MAINTENANCE
CHARGING TIMES
The time required for the G1100 to charge a normally discharged battery
is shown below. Deeply discharged batteries may take longer to charge
depending on the depth of discharge (DOD). The charge time is based on an
average depth of discharge to a fully charged battery.
*Note: The above table is for reference purposes only. Actual data may differ due to battery conditions. The
time required for the G1100 to charge a normally discharged battery is based on an average DOD of 50%.
The G1100 does not require any maintenance. Do not attempt to open or
repair the battery charger as it will invalidate the limited warranty. A damp
cloth may be used to clean dust, dirt, or other debris off of the battery charger.
BEFORE ATTEMPTING TO CLEAN THE BATTERY CHARGER, MAKE SURE
YOU REMOVE THE AC POWER PLUG FROM THE POWER SOURCE.
WICKED SMART FEATURE
Now That’s Smart, Wicked Smart.™
ABNORMALITY PROTECTION. If the battery charger
is in the Bulk mode for more than 96 hours, the battery
charger will go into an ERROR condition. This feature
prevents damage if the battery is faulty.
BATTERY SIZE
(Ah)
APPROX. TIME TO CHARGE IN HOURS*
6V 12V
2.2
7.2
14
25
30
40
1.5
5.0
8.5
15.5
18.0
24.5
1.5
5.0
8.5
15.5
18.0
24.5
TECHNICAL SPECS
WICKED SMART TIP
RIPPLE. Describes the disturbances by current and voltage. A ripple
voltage may cause damage to other equipment connected to the
battery. Less than 2% is wicked low. This will help increase battery life
and protect equipment from damage.
Now That’s Smart, Wicked Smart.™
Input Voltage AC
Working Voltage AC
Input Current
Efciency
Power
Charging Voltage
Charging Current
Back Current Drain
Ripple
Ambient Temperature
Charger Type
Type of Batteries
Battery Chemistries
Battery Capacity
Housing Protection
Cooling
Noise Level
Dimensions (L x W x H)
Weight
110-120 VAC, 50-60Hz
85-130 VAC, 50-60Hz
600mA RMS Max
85% Approx.
30W Max
7.2/14.4, 7.4/14.7V
(Cold/AGM)
1100mA
<5mA
<2%
0°C to +40°C
7 Step, Fully Automatic,
Switch-Mode
6V & 12V Lead-Acid
Wet, Gel, MF & AGM
2.2-40Ah, Maintains All Battery Sizes
IP65
Natural Convection
<50 dB
6.1 x 2.5 x 1.6 Inches
0.8 Pounds